Membrane Chemical Compatibility
This guide summarizes and compares chemical compatibility data from multiple manufacturers. It provides general guidance on the suitability of different membrane materials for short-term contact under laboratory conditions.
Actual compatibility may vary depending on the chemical concentration, temperature, exposure time, specific membrane formulation and construction, and filter housing material. The ratings below should be used as a general guide; always verify compatibility with the manufacturer for the specific product and application.
| Chemical / Solvent | PTFE | NY | MCE | PES | RC | CA | GF | PVDF | PP |
|---|---|---|---|---|---|---|---|---|---|
| Acetic acid, 25% | R | L | L | L | R | L | R | R | R |
| Acetone | R | R | N | N | R | N | R | N | R |
| Acetonitrile | R | R | N | N | R | L | R | L | L |
| Ammonium hydroxide, 25% | R | R | N | L | L | N | R | L | R |
| Chloroform | R | R | L | N | R | N | R | R | L |
| Dichloromethane | R | L | N | N | R | N | R | L | L |
| Diethyl ether | R | R | L | N | R | L | R | R | L |
| Dimethyl sulfoxide (DMSO) | R | R | N | N | R | N | R | N | R |
| Dioxane, tetrahydrofuran (THF) | R | R | N | N | R | N | R | L | L |
| Ethanol, 70% | R | L | R | R | R | R | R | R | R |
| Ethyl acetate, methyl acetate | R | R | N | N | R | N | R | L | L |
| Formic acid, 25% | R | N | N | N | R | L | R | N/A | R |
| Hexane | R | R | R | R | R | L | R | R | N |
| Hydrochloric acid, 15% | R | L | N | L | N | L | R | L | R |
| Hydrochloric acid, 25% | R | N | N | R | N | N | R | L | L |
| Isopropanol, n-propanol | R | R | L | R | R | R | R | R | R |
| Methanol, 98% | R | R | N | L | R | L | R | R | R |
| Nitric acid, 25% | R | N | L | L | N | N | L | L | R |
| Phosphoric acid, 25% | R | N | L | L | R | L | L | L | L |
| Sodium hydroxide, 3 N (12%) | R | R | N | L | N | N | N | N | L |
| Toluene, benzene | R | R | R | N | R | L | R | R | N |
| Triethanolamine | R | R | L | L | R | R | R | L | N/A |
R – Recommended: Generally suitable for the specified conditions.
L – Limited compatibility: Compatibility may be restricted; preliminary testing is recommended.
N – Not recommended: The material is generally unsuitable for the specified conditions.
N/A – Insufficient data: Compatibility data are not available or are insufficient to provide a recommendation.
L – Limited compatibility: Compatibility may be restricted; preliminary testing is recommended.
N – Not recommended: The material is generally unsuitable for the specified conditions.
N/A – Insufficient data: Compatibility data are not available or are insufficient to provide a recommendation.